| MantelMount control via Bond RF bridge | How the MantelMount is controlled in HA — Bond RF entities, contact sensor mapping, command sequence | reference |
MantelMount is controlled via a Bond RF bridge. No native HA integration — uses assumed_state entities.
Entities:
light.mm_down_up— "Run Button" — toggle starts/stops the motorfan.mm_run— direction control. ON = down, OFF = upbinary_sensor.tv_mount_angle_contact— Zigbee door/tilt sensor. ON = mount down/extended, OFF = mount up/retracted
Command sequence: Toggle run button FIRST, then set direction 1s later. This is how the MM controller works — run first, then direction.
Automation (automation.mantelmount_up_down):
- Triggers on Samsung TV on/off
- TV-off condition:
switch.tv_power(Zigbee power strip L4) must be on - Uses contact sensor as guard (skip if already in correct position) and for retry verification after 20s
How to apply: When modifying mantel mount automation, always preserve run-then-direction sequence and contact sensor verification.