name, description, type
name description type
Check for stale/duplicate entities when automations partially fail HA automations that notify but don't actuate devices — look for duplicate entities from re-paired devices feedback

When an HA automation fires (notifications work) but device actions silently fail, check for duplicate entities. Devices that get re-paired create new entities with raw addresses (e.g., switch.0xa4c138...) while the old named entity goes stale.

Why: Chicken sprinkler automation sent notifications fine but switch.turn_on went to a dead entity. The working device had a new entity with a Zigbee address. Silent failure — no error in HA.

How to apply: When debugging partial automation failures, list all entities matching the device name and check last_changed dates. If the named entity hasn't changed in days but a raw-address entity is active, the device was re-paired. Fix by removing the stale entity and renaming the live one.